WIN Ultrasonic Flow Meters are designed to accurately measure the flow of water and water/glycol solutions in pipe sizes from 1/2" – 2 1/2" in diameter. The no-moving-parts design operates over 7 flow ranges (0.06 to 250 GPM) with excellent low flow performance (up to 100:1 turndown ratio). The WIN meter offers an IP65 enclosure with configurable 4-20 mA, with optional 0-5 V or 0-10 V analog output. This CE approved flow meter handles fluids 32°F to 250°F with maximum pressures up to 400 psi. Units are available an optional detachable LCD display with IP65 enclosure, pushbutton keypad, and Modbus RS485 serial interface.
Applications include:
                                                                                Manufacturer Name | 
                                                                        N/A AW-Lake Company | 
                                                                                Type | 
                                                                        N/A Ultrasonic Flow Meter | 
                                                                                Style | 
                                                                        N/A Inline | 
                                                                                Connection Type | 
                                                                        N/A Male NPT | 
                                                                                Connection Size | 
                                                                        N/A 1" low flow | 
                                                                                Overall Flow Range | 
                                                                        N/A 500:1 turndown | 
                                                                                Flow Range - 1% Accuracy | 
                                                                        N/A 1 to 25 gpm | 
                                                                                Flow Range - 2% Accuracy | 
                                                                        N/A 0.25 to 25 gpm | 
                                                                                Minimum Flow | 
                                                                        N/A 0.05 gpm | 
                                                                                Measuring Accuracy | 
                                                                        N/A ±1.0% of reading over 25:1 turndown, ±2.0% of reading over 100:1 turndown | 
                                                                                Repeatability | 
                                                                        N/A ±0.2% | 
                                                                                Sensing Method | 
                                                                        N/A Direct beam path wetted ultrasonic sensors utilizing differential transit time velocity measurement. | 
                                                                                Fluid Temperature [Min] | 
                                                                        N/A 32 ºF0 ºC | 
                                                                                Fluid Temperature [Max] | 
                                                                        N/A 250 ºF121 ºC | 
                                                                                Ambient Temperature [Min] | 
                                                                        N/A -13 ºF-25 ºC | 
                                                                                Ambient Temperature [Max] | 
                                                                        N/A 131 ºF55 ºC | 
                                                                                Operating Pressure [Max] | 
                                                                        N/A 27.6 bar400 psi | 
                                                                                Pressure Drop | 
                                                                        N/A Less than 1 psi at 4 ft/s, decreating at lower velocities | 
                                                                                Power Supply Requirements | 
                                                                        N/A 20-28V AC/DC; 50/60 Hz, 5 VA maximum | 
                                                                                Isolated Analog Output | 
                                                                        N/A May be programmed for flow rate or temperature. Configurable as 4-20mA (nonisolated). Optional 0-5V or 0-10V output. | 
                                                                                Isolated Totalizing Solid State Contact Closure Pulse Outputs | 
                                                                        N/A Contact Pulse Duration: 1000 ms Contact Ratings: 50mA, 30 VDC max. May be programmed for volume, alarm indication, or Modbus coil indication. Optional: Contact pulse duration (50, 100, or 500 ms) | 
                                                                                Isolated Totalizing Pulse Inputs | 
                                                                        N/A For use with sinking open collector or dry contact outputs. Input rating: 30 VDC, 10 mA maximum Pulse duration: 50 ms minimum | 
                                                                                Process Port Type | 
                                                                        N/A 1" MALE NPT | 
                                                                                Weight | 
                                                                        N/A 8.0 lb |