Print Back

This simple to install, all-in-one unit is fully assembled and factory calibrated for easy installation. They provide proportional analog or pulse outputs that will drive popular data acquisition devices, meters, and analog input cards. In addition to the transmitted flow data, the transmitter also provides visual flow levels on the local scale. The weather tight NEMA 4x cast aluminum enclosure allows for installation outdoors and where liquid-tight seals are required.

Applications include:

  • Batching
  • Industrial process control systems
  • Mobile hydraulic equipment
  • Computer or PLC controlled hydraulic system monitoring
Unit of Measure

Technical Specs

Manufacturer Name

N/A AW-Lake Company

Motion Item Number

N/A 02962929

MINO

N/A 05596X20402

UOM

N/A EA

Type

N/A Flow Rate Transmitter

Port Size Range

N/A 3/4" - 1"

Material

N/A Brass

Operating Pressure [Max]

N/A 40 bar600 psi

Fluid Media

N/A Air & Gases

Porting/Thread Type

N/A 3/4" NPTF, dry seal

Flow Range - Liquid

N/A 1 to 10 gpm

Flow Range - Air

N/A 10 to 100 scfm

Optional Flow Direction

N/A Standard Flow, Uni-Directional

Measuring Accuracy

N/A ±2.0% of Full Scale

Repeatability

N/A ±1% of full scale

Flow Measuring Range

N/A 0.1 to 150 gpm0.5 to 550 L/min1 to 600 slps2 to 1300 scfm

Operating Temperature [Max]

N/A 185 ºF85 ºC

Standard Calibration Fluids

N/A Air meters: air at 70°F (21°C), 1.0 sg and 100 PSIG (6.8 Bar) Oil meters: DTE 25® at 110°F (43°C), 0.873 sg Water meters: tap water at 70°F (21°C), 1.0 sg

Filtration Requirements

N/A 74 micron filter or 200 mesh screen minimum

Viscosity

N/A Standard viscosities up to 110 cSt. For viscosities between 110 to 430 cSt contact factory.

Process Port Type

N/A 3/4" NPT

Electronic Transmitter Performance

Power Requirements

N/A 12-24 VDC, Regulated

Load Driving Capacity

N/A 0-5 VDC (regulated): Minimum load resistance 1000 Ω. 1-5 VDC* (regulated): Minimum load resistance 25 K Ω. 4-20mA: Load resistance is dependent on power supply voltage. Max Loop Load (Ω) = 50 (Power supply volts – 12). Square Wave Pulse: Minimum load resistance 1000 Ω. Use the following equation to calculate maximum load resistance:

Transmission Distance

N/A <200 feet recommended for 0-5 VDC (regulated) and square wave pulse. 4-20mA and 1-5 VDC (regulated) are limited only by wire resistance and power supply voltage.

Over-Current Protection

N/A 35 mA

Resolution

N/A 10-bit (0.1%)

Response Time

N/A <100 milliseconds

Non-wetted Components Materials

Enclosure & Cover Material

N/A Painted Aluminum

Seals Material

N/A Buna-N®

Window Material

N/A Pyrex®

Din Connector Material

N/A Polyamide

Wetted Components Materials

Casing & End Ports Material

N/A Brass

Seals Material

N/A Buna-N (STD), EPR, FKM or Kalrez®

Transfer Magnet Material

N/A PTFE coated Alnico

All Other Internal Parts Material

N/A Stainless Steel

Dimensions

A

N/A 7-5/32 in182 mm

B

N/A 2-15/16 in75 mm

C

N/A 4-1/2 in114 mm

D

N/A 1-7/8 in47 mm

E

N/A 5 in127 mm

F

N/A 2-7/8 in73 mm

Benefits

N/A

    Simple to Install
    All transmitters are factory calibrated and ship fully assembled. Simply install the transmitter into your system and apply power. No straight plumbing required at inlet or outlet.

    Industry Standard Outputs
    Transmitters provide proportional analog or pulse outputs that will drive popular data acquisition devices, meters and analog input cards.

    Direct Reading
    All transmitters provide a visual indication of flow rate that matches the transmitted output.

    Weather-Tight Construction
    The rugged cast aluminum enclosure is built to NEMA 4X standard and allows installation outdoors and in environments where liquid tight seals are required.

    Rugged and Reliable
    Without delicate internal components to break, abrade or corrode, the flow transmitter will provide many years of low-maintenance service.

Quick Ship

Quantity Available

N/A {Unknown}

*1-5 Pieces

N/A {Unknown}

*6-10 Pieces

N/A {Unknown}

Std Lead Time

N/A {Unknown}