The JV-UF is designed for low viscosity fluids (solvents, scale inhibitor, methanol, DEF) thanks to the exceptionally tight clearances around the gears which prevent fluid from slipping past. This meter can measure very low flow rates (as low as 0.0005 gpm with a 5cP fluid and as high as 20 gpm).

Applications include:

  • Chemical injection
  • Fuel injection & dosing systems
  • Test stands
  • Hydraulic positioning systems
  • Coolant & lubrication monitoring
Unit of Measure

Manufacturer Name

AW-Lake Company

UOM

EA

Type

Positive Displacement Gear Flow Meter

Flow Range

0.005 to 0.25 gpm0.002 to 1.0 L/min0.72 to 360 gal/d

Housing Seal

FKM o-ring

Port Type

NPT

Sensor Hole

2x M14x1.5

Measuring Accuracy

±0.5% optional with select sensors ±1.5% over full range (viscosity ≥ 5cP) ±2.5% over full range (viscosity ≥ 5cP) for JV-01UF

Repeatability

± 0.05%

Operating Pressure [Max]

345 bar5000 psi

Ports

NPT standard, BSPP optional

Turndown

up to 500:1

Calibration

7-point logarithmic calibration

Resolution

302600 pulses/gal80.0 pulses/cm³

Filtration

15 µm

Process Port Type

1/4" NPT

Weight

3.6 lb