The HUB-40EX Flow Sensor is certified for hazardous areas by CSA (US & Canada), ATEX, and IECEx. It features a NEMA 4X enclosure to protect from environmental conditions and has an integrated swivel union, allowing users to rotate for easy wiring. The HUB-40EX puts out a square wave output signal with a duty cycle of approximately 50%, which is protected by a self-resetting fuse. The easy thread-in installation means you are up and running in minutes.

Available Outputs:

  • Frequency (square wave with 50% duty cycle)

EX Certifications:

  • CSA (US & Canada)
  • ATEX
  • IECEx

Recommended Sensors

Unit of Measure

Manufacturer Name

N/A AW-LAKE COMPANY

Type

N/A Flow Sensor

EX Certification

N/A cCSAus

Junction Box Options

N/A Aluminum junction box

Sensor Type

N/A Hall sensor (sinking version)

Termination

N/A Terminal block

Supply Voltage

N/A 10 to 24 V

Supply Current

N/A 12 mA at 24 VDC 65 mA Maximum 8 mA at 12 VDC

Sensor/Monitor Frequency Output

N/A Flow dependent, 0.5 Hz minimum

Output Amplitude

N/A VHIGH = VSUPPLY - 0.7 Volts VLOW = 0 Volts

Duty Signal

N/A 50% ± 15%

Connections

N/A Cable with 1/2” male NPT Terminal block, 1/2” female NPT conduit entrance

Enclosure Rating

N/A TYPE 4X

cCSAus Certification

N/A Class I, Div. I, Groups C, D Class II, Div. I, Groups E, F, G Class III

ATEX Certification

N/A II 2 G, Ex d IIB+H2 T5 Gb, Ta = -40°C to +60°C

IECEx Certification

N/A Ex d IIB+H2 T5 Gb Ta = -40°C to +60°C

Operating Temperature [Min]

N/A -20 ºC-4 ºF

Operating Temperature [Max]

N/A 60 ºC140 ºF

A

N/A 1.7 in42.6 mm

B

N/A 3.6 in91.8 mm

C

N/A 4.5 in115.24 mm

D

N/A 3.5 in90 mm

N/A

  • Choose from Hazardous area certification options including: cCSAus or ATEX/IECEx
  • Square wave output signal has a duty cycle of approximately 50%.
  • For use with all AW-Lake EX flow meters.

N/A

Up and Running in Minutes
Easy thread-in installation. A quick setup procedure allows you to have the sensor working with just a few simple installation steps.

Flexible Mounting
Because of the integral swivel union, the HUB-40EX unit can be rotated 360° for easy wiring. Options available to fit any AW Gear Meter or Turbine Meter.

Weather-Proof Enclosure
NEMA 4X enclosure provides environmental protection from moisture and debris.

Built-In Protection
The signal outputs are protected by a selfresetting fuse with a 50 mA nominal trip point.