The FlowStat ES Paddle Wheel Flow Meter with integral sensor provides for very simple installation and operation. The economic yet sturdy polypropylene body provides durability at a lower cost. Like its stainless steel cousin, FlowStat ES is offered with multiple outputs to choose from in addition to visual indication of flow through its optional clear cover where you can see the Rotor Flow. The straight fluid path and large spinning rotor means there is minimal pressure drop.

Applications include:

  • Chillers & Cooling Systems
  • Medical Equipment
  • HVAC
  • Batching & Industrial Control
Unit of Measure

Manufacturer Name

N/A AW-Lake Company

Motion Item Number

N/A 03359255

MINO

N/A 05596X75375

UOM

N/A EA

Type

N/A Flowstat 5GPM Meter

Port Size Range

N/A 1/2" NPT

Medium

N/A Fluid

Measuring Accuracy

N/A 2% of full-scale

Repeatability

N/A ±0.5% of full-scale

Flow Measuring Range

N/A 5 gpm

Turn Down Ratio

N/A 10:1

Fluid Temperature Range

N/A 20-150°F

Maximum Operating Pressure

N/A 150 psi

Filtration Requirements

N/A 150 Micron Filter recommended

Standard Calibration Fluid

N/A Tap water at 70°F Temperature (21°C), 1.0 sg

Options

N/A None

Process Port Type

N/A 1/2" NPT

Output

N/A Voltage

Casing Material

N/A Glass-Filled Polypropylene

Cover Material

N/A Clear polycarbonate

Seal Material

N/A Buna-N®

Impeller Material

N/A Acetal Copolymer

Bearing Material

N/A PEEK (Polyetheretherketone)

Shaft Material

N/A Stainless Steel

Encapsulant Material

N/A Epoxy

Strain Relief Material

N/A Nylon

Lock Ring Material

N/A Glass-Filled Polypropylene

Wire Insulation Material

N/A High-Temperature PVC

Power Requirements

N/A 12-24 VDC, Regulated

Maximum Current

N/A 25 mA DC, Regulated

Minimum Load resistance

N/A 1000 Ω

Maximum Transmission Distance

N/A 200 feet recommended

Resolution

N/A Infinite

Response Time

N/A < 5 seconds to 90% (step change)

A

N/A 2.06 in

B

N/A 1.14 in

D

N/A 2.48 in

E

N/A 3.70 in

F

N/A 3.45 in

CL

N/A 120 ft

CL1

N/A 1.88 in

N/A

    Value Pricing
    Low cost operation combined with low cost maintenance, equals better bottom line savings for your operation.

    Encapsulated Circuitry
    Withstands the harshest environments.

    Several Outputs Available
    The standard interface is a 2-wire, 4-20mA current loop. Sensor signal may be transmitted on a low cost wire without degradation. Pulse, relay and 0-5 VDC (regulated) are also available.

    Connects Directly to your Flow Monitoring Instruments
    Can be connected directly to analog acquisition cards, chart recorders or other monitoring instruments, without external signal conditioning.

    Simply Plumb and Apply Power
    Comes factory calibrated to your flow range specifications.

Quantity Available

N/A {Unknown}

*1-5 Pieces

N/A {Unknown}

*6-10 Pieces

N/A {Unknown}

Std Lead Time

N/A {Unknown}