The FlowStat Paddle Wheel Flow Meter with integral sensor provides for very simple installation and operation. The sturdy Stainless Steel body provides durability and a long service life. FlowStat is offered with multiple outputs to choose from in addition to visual indication of flow through its optional clear cover where you can see the Rotor Flow. The straight fluid path and large spinning rotor means there is minimal pressure drop.

Applications include:

  • Chillers & Cooling Systems
  • Solar Power Systems
  • HVAC
  • De-Icing/Anti-Icing
Unit of Measure

Manufacturer Name

N/A AW-Lake Company

Type

N/A Flowstat 2.5GPM Meter

Port Size Range

N/A 1/2" NPT

Medium

N/A Fluid

Measuring Accuracy

N/A ±2% of full scale

Repeatability

N/A ±0.5% of full-scale

Flow Rate

N/A 2.5 gpm

Turn Down Ratio

N/A 10:1

Fluid Temperature Range

N/A 20-225°F (-7° to 107°)

Maximum Operating Pressure

N/A 14 bar200 psi

Filtration Requirements

N/A 150 Micron Filter recommended

Standard Calibration Fluid

N/A Water at 70°F Temperature (21°C), 1.0 sg

Options

N/A Low Flow Option

Process Port Type

N/A 1/2" NPT

Output

N/A Current

Casing Material

N/A Stainless Steel 316

Cover Material

N/A Clear polycarbonate

Seal Material

N/A Buna-N®

Impeller Material

N/A Acetal Copolymer

Bearing Material

N/A PEEK (Polyetheretherketone)

Shaft Material

N/A 316 Stainless Steel

Encapsulant Material

N/A Epoxy

Strain Relief Material

N/A Nylon

Lock Ring Material

N/A Stainless Steel

Wire Insulation Material

N/A High-Temperature PVC

Power Requirements

N/A 12-24 VDC, Regulated, Loop powered

Load Driving Capacity

N/A Use the following equation to calculate maximum load resistance: Max Loop Load (Ω) = 50 (Power supply volts – 12).

Resolution

N/A Infinite

Response Time

N/A 2 seconds to 90% (step change)

Over-current limit

N/A Self limiting at 35 mA

Other protection

N/A Reverse polarity

A

N/A 1.94 in49 mm

B

N/A 1.13 in29 mm

C

N/A 2.00 in51 mm

D

N/A 2.45 in62 mm

E

N/A 3.70 in94 mm

F

N/A 2.63 in67 mm

N/A

    Choice of Three Port Sizes
    Select from 1/2" , 3/4" or 1" NPT porting to meet system requirements.
    NOTE: Using reduced ID fittings will affect calibrated range.

    Encapsulated Circuitry
    Withstands the harshest environments.

    Several Outputs Available
    The standard interface is a 2-wire, 4-20mA current loop. Sensor signal may be transmitted on a low cost wire without degradation. Pulse, relay and 0-5 VDC (regulated) are also available.

    Connects Directly to your Flow Monitoring Instruments
    Can be connected directly to analog acquisition cards, chart recorders or other monitoring instruments, without external signal conditioning.

    Simply Plumb and Apply Power
    Comes factory calibrated to your flow range specifications.

Quantity Available

N/A {Unknown}

*1-5 Pieces

N/A {Unknown}

*6-10 Pieces

N/A {Unknown}

Std Lead Time

N/A {Unknown}