This simple to install, all-in-one unit is fully assembled and factory calibrated for easy installation. They provide proportional analog or pulse outputs that will drive popular data acquisition devices, meters, and analog input cards. In addition to the transmitted flow data, the transmitter also provides visual flow levels on the local scale. The weather tight NEMA 4x cast aluminum enclosure allows for installation outdoors and where liquid-tight seals are required.
Applications include:
- Batching
- Industrial process control systems
- Mobile hydraulic equipment
- Computer or PLC controlled hydraulic system monitoring
- Technical Specs
- Electronic Transmitter Performance
- Non-wetted Components Materials
- Wetted Components Materials
- Dimensions
- Benefits
- Quick Ship
Manufacturer Name |
N/A AW-Lake Company |
Motion Item Number |
N/A 02962613 |
MINO |
N/A 05596X20086 |
UOM |
N/A EA |
Type |
N/A Flow Rate Transmitter |
Port Size Range |
N/A 1/4" - 1/2" |
Material |
N/A Brass |
Operating Pressure [Max] |
N/A 40 bar600 psi |
Fluid Media |
N/A Air & Gases |
Porting/Thread Type |
N/A 1/2" BSPP |
Flow Range - Liquid |
N/A 0.2 to 2 gpm |
Flow Range - Air |
N/A 4 to 23 scfm |
Optional Flow Direction |
N/A Standard Flow, Uni-Directional |
Measuring Accuracy |
N/A ±2.0% of Full Scale |
Repeatability |
N/A ±1% of full scale |
Flow Measuring Range |
N/A 0.1 to 150 gpm0.5 to 550 L/min1 to 600 slps2 to 1300 scfm |
Operating Temperature [Max] |
N/A 185 ºF85 ºC |
Standard Calibration Fluids |
N/A Air meters: air at 70°F (21°C), 1.0 sg and 100 PSIG (6.8 Bar) Oil meters: DTE 25® at 110°F (43°C), 0.873 sg Water meters: tap water at 70°F (21°C), 1.0 sg |
Filtration Requirements |
N/A 74 micron filter or 200 mesh screen minimum |
Viscosity |
N/A Standard viscosities up to 110 cSt. For viscosities between 110 to 430 cSt contact factory. |
Process Port Type |
N/A 1/2" BSPP |
Power Requirements |
N/A 12-24 VDC, Regulated |
Load Driving Capacity |
N/A 0-5 VDC (regulated): Minimum load resistance 1000 Ω. 1-5 VDC* (regulated): Minimum load resistance 25 K Ω. 4-20mA: Load resistance is dependent on power supply voltage. Max Loop Load (Ω) = 50 (Power supply volts – 12). Square Wave Pulse: Minimum load resistance 1000 Ω. Use the following equation to calculate maximum load resistance: |
Transmission Distance |
N/A <200 feet recommended for 0-5 VDC (regulated) and square wave pulse. 4-20mA and 1-5 VDC (regulated) are limited only by wire resistance and power supply voltage. |
Over-Current Protection |
N/A 35 mA |
Resolution |
N/A 10-bit (0.1%) |
Response Time |
N/A <100 milliseconds |
Enclosure & Cover Material |
N/A Painted Aluminum |
Seals Material |
N/A Buna-N® |
Window Material |
N/A Pyrex® |
Din Connector Material |
N/A Polyamide |
Casing & End Ports Material |
N/A Brass |
Seals Material |
N/A Buna-N (STD), EPR, FKM or Kalrez® |
Transfer Magnet Material |
N/A PTFE coated Alnico |
All Other Internal Parts Material |
N/A Stainless Steel |
A |
N/A 6-9/16 in167 mm |
B |
N/A 2-3/16 in56 mm |
C |
N/A 4 in101 mm |
D |
N/A 1-7/8 in47 mm |
E |
N/A 4-7/8 in128 mm |
F |
N/A 2-1/4 in57 mm |
N/A
Simple to Install Industry Standard Outputs Direct Reading Weather-Tight Construction Rugged and Reliable |
Quantity Available |
N/A {Unknown} |
*1-5 Pieces |
N/A {Unknown} |
*6-10 Pieces |
N/A {Unknown} |
Std Lead Time |
N/A {Unknown} |