The JV-BB series of Positive Displacement Flow meters maintain 0.5% accuracy over the full range of the meter, high resolution, and pressure rating up to 6,000 psi. These PD meters are available in 3 body materials (Aluminum, 303 SS, and 316L SS) and were designed for measuring lubricating and nonabrasive fluids with low or medium viscosity.
Applications include:
Manufacturer Name |
N/A AW-Lake Company |
UOM |
N/A EA |
Type |
N/A Positive Displacement Gear Flow Meter |
Flow Range |
N/A 0.5 to 60.0 gpm1.9 to 227 L/min720 to 86400 gal/d |
Housing Seal |
N/A FKM o-ring |
Port Type |
N/A Code 62 Hydraulic Flange |
Sensor Hole |
N/A Quad-4 |
Measuring Accuracy |
N/A ±0.25% optional with select sensors ±0.5% over full range with 30cP fluid |
Repeatability |
N/A ± 0.1% |
Operating Pressure [Max] |
N/A 345 bar5000 psi |
Ports |
N/A 1-1/4" SAE code 62 flange pattern standard NPT, JIC & SAE flanges available upon request. |
Turndown |
N/A up to 150:1 |
Calibration |
N/A 7-point logarithmic calibration |
Resolution |
N/A 1600 pulses/gal0.42 pulses/cm³ |
Filtration |
N/A 200 µm |
Process Port Type |
N/A 1-1/4" SAE CODE 62 |
Weight |
N/A 31.0 lb |
Housing Material |
N/A 7075 High Strength Aluminum |
Gears Material |
N/A Stainless Steel (DIN 1.4122) |
Bearing Material |
N/A Stainless Steel (DIN 1.4122) |
O-Ring Material |
N/A FKM |
Shaft Material |
N/A 402 Stainless Steel |
Bolts Material |
N/A Zinc Flake Coated Carbon Steel (Inconel 718 optional) |