WIN Ultrasonic Flow Meters are designed to accurately measure the flow of water and water/glycol solutions in pipe sizes from 1/2" – 2 1/2" in diameter. The no-moving-parts design operates over 7 flow ranges (0.06 to 250 GPM) with excellent low flow performance (up to 100:1 turndown ratio). The WIN meter offers an IP65 enclosure with configurable 4-20 mA, with optional 0-5 V or 0-10 V analog output. This CE approved flow meter handles fluids 32°F to 250°F with maximum pressures up to 400 psi. Units are available an optional detachable LCD display with IP65 enclosure, pushbutton keypad, and Modbus RS485 serial interface.
Applications include:
Manufacturer Name |
N/A AW-Lake Company |
Type |
N/A Ultrasonic Flow Meter |
Style |
N/A Inline |
Connection Type |
N/A Male NPT |
Connection Size |
N/A 1" low flow |
Overall Flow Range |
N/A 500:1 turndown |
Flow Range - 1% Accuracy |
N/A 1 to 25 gpm |
Flow Range - 2% Accuracy |
N/A 0.25 to 25 gpm |
Minimum Flow |
N/A 0.05 gpm |
Measuring Accuracy |
N/A ±1.0% of reading over 25:1 turndown, ±2.0% of reading over 100:1 turndown |
Repeatability |
N/A ±0.2% |
Sensing Method |
N/A Direct beam path wetted ultrasonic sensors utilizing differential transit time velocity measurement. |
Fluid Temperature [Min] |
N/A 32 ºF0 ºC |
Fluid Temperature [Max] |
N/A 250 ºF121 ºC |
Ambient Temperature [Min] |
N/A -13 ºF-25 ºC |
Ambient Temperature [Max] |
N/A 131 ºF55 ºC |
Operating Pressure [Max] |
N/A 27.6 bar400 psi |
Pressure Drop |
N/A Less than 1 psi at 4 ft/s, decreating at lower velocities |
Power Supply Requirements |
N/A 20-28V AC/DC; 50/60 Hz, 5 VA maximum |
Isolated Analog Output |
N/A May be programmed for flow rate or temperature. Configurable as 4-20mA (nonisolated). Optional 0-5V or 0-10V output. |
Isolated Totalizing Solid State Contact Closure Pulse Outputs |
N/A Contact Pulse Duration: 1000 ms Contact Ratings: 50mA, 30 VDC max. May be programmed for volume, alarm indication, or Modbus coil indication. Optional: Contact pulse duration (50, 100, or 500 ms) |
Isolated Totalizing Pulse Inputs |
N/A For use with sinking open collector or dry contact outputs. Input rating: 30 VDC, 10 mA maximum Pulse duration: 50 ms minimum |
Process Port Type |
N/A 1" MALE NPT |
Weight |
N/A 8.0 lb |