Using the Transit Time measurement principle, the CUTT Clamp-On Ultrasonic Flow Meter fastens on the outside of vertical or horizontal pipes ranging in size from ½” through 48”.  Housed in a water- and dust-tight NEMA4X polycarbonate enclosure, the Clamp-On Ultrasonic Flow Meters offer Isolated 4-20 mA and 0-5 V analog output. The non-intrusive flow measurement allows measurement of the most “corrosive liquids” that would damage standard flow meters. Clamp-on transducers can accommodatemore

Unit of Measure

Manufacturer Name

AW-Lake Company

Type

Ultrasonic Flow Meter

Style

Clamp-on

Power Input

100-240VAC, 50/60Hz, 10VA Max.

Enclosure & Electronics Protection

NEMA4X (IP66) polycarbonate enclosure

Enclosure Temperature Rating

-5 to 140 ÂşF-20 to 60 ÂşC

Intrinsic Safety Rating

QTY 2 ISB Intrinsic Safety Barriers for transducer installation in Class 1 Div 1, Groups C, D; Class 2, Groups E, F, G; Class 3; Type 4

Transducers

E16B pair, clamp-on for 2" to 48" (50 mm to 1200 mm) pipes

Transducer Mounting Hardware

TMK-B1; Includes stainless brackets, mounting clamps, alignment bar, and silicone coupling compound.

Cables & Connections

25 ft/7.6 m pair triaxial with BNC connectors and seal jackets

Serial Communications

None

Control Relays

2 relays, rated 5 amp SPDT, programmable

Measuring Accuracy

±1.0% of reading from 1.5 to 40 ft/sec (0.5 to 12.0 m/sec) and ±0.015 ft/sec (±0.0046 m/sec) for velocity below 1.5 ft/sec (0.46 m/sec).

Repeatability & Linearity

±0.25%

Flow Measuring Range

0.07 to 40 ft/s0.02 to 12 m/s

Pipe Diameter

SE16A: 0.5" to 4" (15 mm to 100 mm) SE16B: 2" to 48" (50 mm to 1200 mm)

Pipe Materials

Any metal or plastic sonic conducting materials, including carbon steel, stainless steel, ductile iron, concrete lined ductile iron, cast iron, PVC, HDPE, PVDF, fiberglass, copper, brass, aluminum, and pipes with bonded liners, including epoxy, rubber, and PTFE.

Operating Frequency

SE16A: 2.56 MHz SE16B: 1.28 MHz

Transducer - Operating Temperature Range

-40 to 300 ÂşF-40 to 150 ÂşC

Electronics - Operating Temperature Range

-5 to 140 ÂşF-20 to 60 ÂşC

Analog Output

Isolated 4-20mA/0-5V, 1000 ohm load max., programmable offset

Hazardous Area Certifications

Non-Incendive for Class I Division 2, Groups A,B,C,D Optional: Intrinsically safe for Class I Division 1, Groups A,B,C,D

Approximate Shipping Weight

12 lb5.5 kg